Add: 701 YuLon Building No.16 DongYuan Road, ChangPing Town, DongGuan City, GuangDong Province
Tel: 0769-83507020
Fax: 0769-83507027
E-mail: info@hashima.com.cn
Trouble shooting of interlining | |||||||||||||||||||||||||
![]() |
|||||||||||||||||||||||||
The above drawing is basic circuit of heater for fusing press. There are various type of machine that has 4 sets, 6 sets or 6sets of heater. Thermostat is checking temperature of heater through thermo sensor during heating up. Before reach to setting temperature, DC5V-20V . is on terminal No. (5)and (6) to terminal No.(3) and (4). Under this condition, thermo lamp on the thermostat and SSR lamp are on. When the electric current is on terminal No.(3) and (4), the electric current is on between terminal No.(1) and (2). In other word, the voltage is 0V between terminal (1) and (2). Because the electric currency is on from terminal No. (1) to (2). Heater has temperature sensor. When temperature is too high, the voltage of terminal No.(5) and (6) will be 0V and terminal No.(3) and (4) will be 0V. Under this condition, the some voltage between terminal No.(1) and (2) will is be on. It depends on the each machine specification. It is 220v or 380v. in this case, thermo lamp on thermostat and SSR lamp are off. |
|||||||||||||||||||||||||
Thermostat unit dose not work | |||||||||||||||||||||||||
First please check main power. Input voltage to a thermostat is 100V or 200V. check this input voltage and out put Voltage (DC5-20V) by tester. If the thermostat dose not receive input voltage 100V or 200V, it will not work correctly. |
|||||||||||||||||||||||||
Actual temperature dose not reach setting temperature. | |||||||||||||||||||||||||
We need to check a signal from thermostat to SSR (solid state replay). After checking input voltage to thermostat, check out put voltage DC5V-20V from Thermostat. Checking SSR movement. Set temperature at 130℃. Measure the voltage between terminal no 1 and 2. In case of 0 V, electricity should reach to heater. If temperature dose not increase, The heater has defect. If the machine has plural of heater, some of them might has Defect. Please check heater piece by piece. |
|||||||||||||||||||||||||
Atual temperature is over setting temperature | |||||||||||||||||||||||||
Thermo sensor is defect SSR is defect Heater with thermo sensor is defect. |
|||||||||||||||||||||||||
Matching actual temperature and setting temperature. | |||||||||||||||||||||||||
Check actual temperature by thermo paper. (For example), when setting temperature is 130℃, the thermo paper shows 140℃. This means actual temperature is higher 10℃ than setting temperature. In case of analog thermostat, Set temperature at 140℃ and adjust temperature correct dial that thermo lamp Turn on and off at 140℃. After this adjustment, actual temperature mach setting Temperature In case of digital thermostat It depends on a model. We use different thermostat unit. Please contact us.(hashima) |
|||||||||||||||||||||||||
<Causes and countermeasures in regard to troubles> | |||||||||||||||||||||||||
|
DongGuan NISHIMA Machinery CO.,Ltd www.hashima.com.cn © Copyright Guangdong ICP 12006811-3sitemap
701 YuLon Building No.16 DongYuan Road,ChangPing Town,DongGuan City. Tel: 0769-83507020 Fax: 0769-83507027 E-mail: info@hashima.com.cn